SWITCHBOARD METER
* Maximum Demand,
Bimetallic Panel Meter

Bimetallic (Maximum Demand) Panel Meter are designed for testing thermal load of transformers, cables, electrical machines, etc. They can indicate average rms current value in a setting period of 15 minutes.
* SCALE 240O WIDE ANGLE PANEL METER
* SCALE 90O ANALOG PANEL METER
¡@
¡@
*RATING TABLE
|
BIMETALLIC (MAXIMUM DEMAND) AMMETERS |
|
|
TYPE |
BE-96 |
|
DELAY TIME |
15 minutes |
|
ON C.T. RATIO /5A |
10A, 15A, 25A, 40A, 60A, 100A, 150A, 250A, 400A, 600A, 1000A~ |
: SCALE 90O
: SCALE 240O
|
AC Ammeter |
||||||||
| TYPE | BE-48 | BE-72 | BE-96 | BE-144 | ||||
| SIZE | 48x48 mm | 72x72 mm | 96x96 mm | 144x144 mm | ||||
| Direct |
CT /1A; /5A |
Direct |
CT /1A; /5A |
Direct |
CT /1A; /5A |
Direct |
CT /1A; /5A |
|
| 1A | ||||||||
| 5A | |
|
||||||
| 10A | |
|
||||||
| 15A | |
|||||||
| 20A | |
|||||||
| 25A | |
|||||||
| 30A | |
|||||||
| 40A | |
|||||||
| 50A | |
|||||||
| 60A | |
|||||||
| 75A | |
|||||||
| 100A | |
|||||||
| 120A | |
|||||||
| 150A | |
|||||||
| 200A | |
|||||||
| 250A | |
|||||||
| 300A | |
|||||||
| 400A | |
|||||||
| 500A | |
|||||||
| 600A | |
|||||||
| 800A | |
|||||||
| 1000A | |
|||||||
| 1200A | |
|||||||
| 1250A | |
|||||||
| 1500A | |
|||||||
| 2000A | |
|||||||
| 2500A | |
|||||||
| 3000A~ | |
|||||||
: SCALE 90O
: SCALE 240O
|
AC Voltmeter |
||||
| TYPE | BE-48 | BE-72 | BE-96 | BE-144 |
| SIZE | 48x48 mm | 72x72 mm | 96x96 mm | 144x144 mm |
| 100V | ||||
| 300V | ||||
| 500V | ||||
| 600V | ||||
: SCALE 90O
: SCALE 240O
|
DC Ammeter |
||||||||
| TYPE | BE-48 | BE-72 | BE-96 | BE-144 | ||||
| SIZE | 48x48 mm | 72x72 mm | 96x96 mm | 144x144 mm | ||||
|
0 Left 50,60, 75mV |
0 Central 50,60, 75mV |
0 Left 50,60, 75mV |
0 Central 50,60, 75mV |
0 Left 50,60, 75mV |
0 Central 50,60, 75mV |
0 Left 50,60, 75mV |
0 Central 50,60, 75mV |
|
| 10A | ||||||||
| 15A | |
|
||||||
| 20A | |
|
||||||
| 25A | |
|||||||
| 30A | |
|||||||
| 40A | |
|||||||
| 50A | |
|||||||
| 60A | |
|||||||
| 80A | |
|||||||
| 100A | |
|||||||
| 150A | |
|||||||
| 200A | |
|||||||
| 300A~ | |
|||||||
: SCALE 90O
: SCALE 240O
|
DC Voltmeter |
||||||||
| TYPE | BE-48 | BE-72 | BE-96 | BE-144 | ||||
| SIZE | 48x48 mm | 72x72 mm | 96x96 mm | 144x144 mm | ||||
|
0 Left |
¡@ 0 Central |
0 Left |
0 Central |
0 Left |
0 Central |
0 Left |
0 Central |
|
| 60mV | ||||||||
| 10V | |
|
||||||
| 20V | |
|
||||||
| 40V | |
|||||||
| 100V | |
|||||||
| 150V | |
|||||||
| 200V | |
|||||||
| 300V | |
|||||||
| 400V | |
|||||||
| 500V | |
|||||||
¡@
|
HZ Meter |
||||
| TYPE | BE-48 | BE-72 | BE-96 | BE-144 |
| SIZE | 48x48 mm | 72x72 mm | 96x96 mm | 144x144 mm |
| by REEDS | ¡@
¡@ |
7 REEDS | 11 REEDS | |
|
47~53HZ 57~63HZ |
45~55HZ 55~65HZ |
|||
| by POINTER | Frequency : 50 / 60 HZ | |||
| Range: 45~55Hz, 45~65Hz, 55~65Hz | ||||
| Voltage: 110V, 220V, 380V, 440V | ||||
: SCALE 90O
: SCALE 240O
|
POWER FACTOR (
COS |
|||
| TYPE | BE-72 | BE-96 | BE-144 |
| SIZE | 72x72 mm | 96x96 mm | 144x144 mm |
| Single phase | |||
| Three phase 3 wires | |||
| Three phase 4 wires | |||
: SCALE 90O
: SCALE 240O
|
WATTMETER |
|||
| TYPE | BE-72 | BE-96 | BE-144 |
| SIZE | 72x72 mm | 96x96 mm | 144x144 mm |
| Single phase | |||
| Three phase 3 wires | |||
| Three phase 4 wires | |||
: SCALE 90O
: SCALE 240O
|
VARMETER |
|||
| TYPE | BE-72 | BE-96 | BE-144 |
| SIZE | 72x72 mm | 96x96 mm | 144x144 mm |
| Single phase | |||
| Three phase 3 wires | |||
| Three phase 4 wires | |||
¡@
*PANEL LAYOUT
(BE-96)
(BE-72)
(BE-48)
(BE-144)
*VOLT
METER
MEASURING RANGE :
..MOVING COIL TYPE : 100A-50A DC , 3V-600V DC
..MOVING IRON TYPE: 1A-60A AC , 150V-600V AC
..RECTIFIER TYPE: 3V-600V AC , 1A-5A AC
ACCURACY : Class 1.5%
AC AMPERE OVERLOAD SCALE: 200%,300%,500%
DC Ammeters above 50A require a basic
50 mV meter combined with an external shunt.
AC Ammeters above 100 A require a basic
5A meter combined with an external CT.
AC Voltmeters above 600 Volts require a
basic 150V meter combined with an external PT.
*Hz METER
ACCURACY class 1.5%
WORKING POSITION ; VERTICAL
RATED VOLTAGE: 110V,220V,380V,500V.
LIMIT OF VOLTAGE FLUCTUATION: 20%
CONSUMPTION: Max. 15 mA.
TEST VOLTAGE: 2KV,50c/s
MEASURING RANGE: 45-65 c/s
COMPOSITION: Glass window ,ABS Resin frame and case,
PC glass fiber base mounting fitting included.
COLOR: lack base and frame, white scale plate and meter body.
POINTER: Stick shape in black color.